ESP-101
Plasma Arc Cutting System
0558007871
Instruction Manual (English)
This manual provides installation and operation instructions for the following ESP-101 cutting packages starting with Serial
No.: PxxJ943xxx
Consoles:
P/N 0558004880 - ESP-101 460V
P/N 0558005215 - ESP-101 380-400V CE
Vista de página 0
1 2 3 4 5 6 ... 33 34

Resumo do Conteúdo

Página 1 - Plasma Arc Cutting System

ESP-101Plasma Arc Cutting System0558007871Instruction Manual (English)This manual provides installation and operation instructions for the following E

Página 2 - USER RESPONSIBILITY

14SECTION 2 DESCRIPTION2.6 System and Optional AccessoriesRemote Junction Box ...

Página 3 - TABLE OF CONTENTS

153.1 General Proper installation is important for satisfactory and trouble-free operation of the ESP-101 cutting package. It is suggested that

Página 4

16SECTION 3 INSTALLATION3.5 Primary Input ConnectionsThe ESP-101 460V consoles are equipped with approximately 15 ft. of 4-conductor input

Página 5 - SECTION 1 SAFETY PRECAUTIONS

17ESP-101Input Requirements Input & Gnd FuseVolts Phase AmpsConductor SizeCU/AWG Amps380(CE) 3 30 6 mm240400(CE) 3 29 6 mm240460 3 25 8 35Table 3-

Página 6

183.5.1 TUA2 Auto-Transformer Primary Input ConnectionsSECTION 3 INSTALLATIONConnecting a Multi-Voltage VersionThe ESP-101 460V version is equipped

Página 7

19SECTION 3 INSTALLATIONThe TUA2 Auto-Transformer is not equipped with an input power cable. A 4/c, type SO (90 °C) cable or equivalent is recom-mend

Página 8

20SECTION 3 INSTALLATIONFigure 3-4. Input Connections / Fuse ReplacementConnect your air supply to the inlet connection of the lter/regulator.3.5.2

Página 9

21SECTION 3 INSTALLATIONFigure 3-5. Mechanical Cutting Interface Diagram CNC Interface Connection3.6 CNC Interface ConnectionFront ViewNote:If repla

Página 10 - SECTION 2 DESCRIPTION

22SECTION 3 INSTALLATIONStart signal (pin M)Use a relay to connect this pin to “Common” (pin N) to start the cutting process.If a transistor is used

Página 11 - SECTION 3 INSTALLATION

23SECTION 3 INSTALLATIONMAKE SURE POWER SWITCH ON CONSOLE IS IN OFF POSITION AND PRIMARY INPUT POWER IS DEENERGIZED.WARNING3.7 Voltage Divider Ad

Página 12

6This equipment will perform in conformity with the description thereof contained in this manual and accompa-nying labels and/or inserts when installe

Página 13

24BEFORE MAKING ANY CONNECTIONS TO THE POWER SOURCE OUTPUT TERMINALS, MAKE SURE THAT ALL PRIMARY INPUT POWER TO THE POWER SOURCE IS DE ENERGIZED OFF

Página 14 - 5/16" ring terminal

25SECTION 3 INSTALLATIONTorch Cable Male ReceptaclePanel ReceptacleTorch Lead Access DoorAir HoseTorch Lead Access Opening1. Open lead access door o

Página 15

26SECTION 3 INSTALLATIONThe Remote Junction Box (RJB) provides a means to extend the total length of the PT-37 Torch. A Remote Junction Box is used i

Página 16

27SECTION 3 INSTALLATIONA. ESP-101 Modications Remove the top and right side panel of the power supply. 1. Redirection of solenoid control wiring

Página 17

28B. Mounting the Remote Junction Box (RJB)1. With the cover removed from the Remote Junction Box, mount the base to a rigid location on the cut-tin

Página 18

29SECTION 3 INSTALLATIONFrom ESP-101Extension Cable Air ConnectionExtension CableTo PT-37 TorchExtension CablePower Connection2. Insert the free end

Página 19

30SECTION 3 INSTALLATIONPanel ReceptacleAir HoseExtension Cable Male ReceptacleC. Connecting to the ESP-101 The Extension Cable is connected to the

Página 20

31ELECTRIC SHOCK CAN KILL.• Do NOT operate the unit with the cover removed.• Do NOT apply power to the unit while holding or carrying the unit.• Do

Página 21

32SECTION 4 OPERATIONC. Output Current Control. Adjustable from 20 to 100 amperes. Calibration marks are to provide a guide in setting cur-rent. Fo

Página 22

33SECTION 4 OPERATIONNote:Most fault signals will remain on for a minimum of 10 seconds. Unit will reset automatically after faults are cleared excep

Página 23

7TABLE OF CONTENTSSECTION TITLE...

Página 24

34SECTION 4 OPERATION4.2 Cutting with the ESP-101A. Make sure that the wall disconnect switch is on and air is supplied to machine. B. Turn on the

Página 25

354.4 Stando and Cut QualityStando (Arc Voltage) has a direct inuence on cut quality and squareness. It is recommended that prior to cuttin

Página 26

36SUMMARYArc voltage is a dependent variable. It is dependent upon cutting amperage, nozzle size, torch stando, cut gas ow rate and cutting speed. A

Página 27 - SECTION 4 OPERATION

374.6 Common Cutting IssuesListed below are common cutting problems followed by the probable cause of each. If problems are determined to be caused

Página 28

38SECTION 4 OPERATION

Página 29

8TABLE OF CONTENTS

Página 30

9SECTION 1 SAFETY PRECAUTIONS1.0 Safety PrecautionsUsers of ESAB welding and plasma cutting equipment have the ultimate responsibility f

Página 31

10SECTION 1 SAFETY PRECAUTIONSWELDING AND PLASMA CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAUTIONS WHEN WELDING OR CUTTING. ASK FOR

Página 32

11SECTION 2 DESCRIPTION2.1 General As shipped, the ESP-101 is fully assembled and ready to cut after being connected to input power, a source of c

Página 33

12SECTION 2 DESCRIPTIONThe ESP-101 plasma cutting system combines the newly redesigned ESP-101 console and PT-37 torch. The PT-37 plasma cutting torc

Página 34

13SECTION 2 DESCRIPTION2.4 Package Ordering Information:The components that are included in the ESP-101 mechanized packages may be purchased separat