18
2. WIRE FEEDER CONTROL RECEPTACLE
This 19-pin receptacle (J1) accepts the control cable from the wire feeder
and handles all the control signals needed to operate a 42 Vac wire feeder.
3. REMOTE CONTROL RECEPTACLE
This receptacle (J2) is provided for an optional 14-pin control cable from the
optional remote pendant, Tig torch control or foot control . This receptacle
is operative only if the PANEL/REMOTE switch on the power source front
panel is in the REMOTE position.
4. CONTACTOR "ON/OFF" SWITCH
This switch provides manual control of the welding contactor when the
PROCESS switch on the control panel is in the MIG position (CV welding).
An example of when to use this switch is when CV carbon arc gouging is
needed or an "Off the Arc" wire feeder with secondary contactor is operated
in the CV mode.
5. AUXILIARY 115 VAC RECEPTACLE
A 115 Vac receptacle is provided to supply power to accessories such as a
water cooler, heated CO
2
regulator, or small hand tools. The receptacle is
rated 115 Vac / 10 amps with a floating neutral.
6. 42VAC AND 115 VAC CIRCUIT BREAKER (CB1 & CB2)
These resetable 10 amp circuit breakers (CB1 & CB2) protect the 42 volt wire
feeder/control and 115 volt auxiliary receptacle circuitry against over current.
(Table 6-1 provides troubleshooting information).