SECTION 3 INSTALLATION
5. Figures 3-3, 3-4 and 3-5 illustrate the input voltage terminal boards and the input voltage link
connections. The particular voltages from which this power source may be operated are stated on the
rating plate. The voltage links were factory set for highest voltage stated on the rating plate (575VAC).
If the power source is to be operated on another stated input voltage, the links must be reset for that
particular input voltage. Always verify the input voltage and check the link arrangement regardless of
factory setting. The voltage links are set up by reconfiguring the copper link bars to the silk-screened
voltage designations for the desired voltage.
Figure 3-3. Input Terminal Board Configuration for 230/460/575 Model
(factory supplied in the 575 configuration)
230 Vac Input 460 Vac Input
575 Vac Input
Figure 3-5 Input Terminal Board Configuration 220/
400 Model (factory supplied in the 400 configuration)
220 Vac Input
400 Vac Input
Figure 3-4 Input Terminal Board Configuration 230/
460 Model (factory supplied in the 460 configuration)
460 Vac Input
230 Vac Input
*
*
*