26
NOTE
"OFF THE ARC" Wire Feeders can use
either MIG (CV) or STICK (CC) Process
Selection. Place the contactor toggle
switch on the accesssory panel (see
Figure 2-5) to the "ON" position.
SECTION 4 OPERATION
return to zero. There is no “HOLD” circuit for the display meters when using the
TIG and STICK process modes.
E. MIG WELDING PRESET PROCEDURE
When the PROCESS switch is placed in the MIG position, the MultiPower 460
is set for CV (constant voltage) welding. The power source will output open
circuit voltage (OCV) when the Mig Gun trigger is depressed. The following
procedure assumes the wire feed and voltage adjustments will be made from
the wire feeder front panel and wire and gas have been installed.
Step 1. Connect wire feeder to MultiPower 460 and set PANEL/REMOTE
switch to REMOTE position.
Step 2. Place the WELD PROCESS switch in the MIG (center) position.
Step 3. Press and release the PRESET button then turn the wire speed
control on the wire feeder to the desired speed shown on the top
digital display window of the MultiPower 460.
Step 4. Turn the VOLTAGE knob on the wire feeder to the desired arc
voltage in the bottom digital display window of the
MultiPower 460.
Step 5. Set the shielding gas flow rate to 35 cfh by activating the gas purge
switch on the wire feeder or pulling the gun trigger and turning the
adjustment knob on the Flowmeter.
Step 6. Connect the work cable to the part to be welded and pull the gun
trigger to start welding. Trim the wire speed and volts as needed for
the desired arc characteristics and weld quality.
Step 1
Step 2
Step 3
Figure 4-1 Standard Mig Setup Procedure