ESAB MultiPower 460 Pulse Manual de Instruções

Consulte online ou descarregue Manual de Instruções para Sistema de solda ESAB MultiPower 460 Pulse. ESAB MultiPower 460 Pulse Instruction manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
0558003754 03 / 2006
MultiPower
460 Pulse
DC WELDING POWER SOURCE
(Shipyard Model)
INSTRUCTION MANUAL
ESAB ITEM NO. 0558003402, MultiPower 460 Pulse - 230/460/575 vac, 3 ph., 60 Hz
Serial Number: Mxxx333xxx
Vista de página 0
1 2 3 4 5 6 ... 51 52

Resumo do Conteúdo

Página 1 - 460 Pulse

0558003754 03 / 2006MultiPower 460 PulseDC WELDING POWER SOURCE(Shipyard Model)INSTRUCTION MANUALESAB ITEM NO. 0558003402, MultiPower 460 Pulse - 230

Página 2 - USER RESPONSIBILITY

10levage, des câbles de grue ou divers cheminsélectriques.g. Empêchez l’apparition de toute humidité, notammentsur vos vêtements, à la surface de l’em

Página 3 - TABLE OF CONTENTS

11Table 2-1. Specifications for MultiPower 460 Pulse2.1. SAFETYBefore the MultiPower 460 Pulse power source is put into operation, thesafety section a

Página 4

12The MultiPower 460 Pulse is a multi-process power source designed for Migshort circuiting, spray and pulse spray transfer (GMAW), flux core (FCAW),T

Página 5 - SECTION 1 SAFETY PRECAUTIONS

13Figure 2-3. Pulse Control PanelSECTION 2 DESCRIPTIONC. CONTROL PANEL DESCRIPTION (Refer to Figures 2-3 and 2-4)1. FAULT LAMP The RED fault lig

Página 6

14DESCRIPTIONSECTION 2When using a DuraDrive 4-30 or DuraDrive 4-48 Wire Feeder, the wire feedspeed is displayed in inches per minute (IPM) in the top

Página 7

15Figure 2-5. MultiPower 4607. INDUCTANCE TRIMThis control is used only in the STANDARD mode and is deactivated in theTIG, STICK and PULSE modes. In

Página 8 - §25249.5 et seq.)

16DESCRIPTIONSECTION 21. POWER ON/OFF SWITCH & LAMPThe main power switch is located on the right front panel of the power source.This switch ener

Página 9

17Figure 2-6. Remote Control PendantDESCRIPTIONSECTION 2NOTEIf a Remote Control Pendant is used forcontinuous current control, place thePANEL/REMOTE s

Página 10

18DESCRIPTIONSECTION 2

Página 11 - DESCRIPTION

19Table 3-1. Recommended Sizes for InputConductors and Line Fuses*Sized per National Code for 80 °C rated copper conductors @ 30 °C ambient. Not more

Página 12

2These INSTRUCTIONS are for experienced operators. If you are not fully familiar with the principlesof operation and safe practices for arc welding a

Página 13 - SECTION 2 DESCRIPTION

201. The primary power leads must be insulated copper conductors. Threepower leads and one ground wire are required. Either rubber coveredcable or co

Página 14

212. Remove the top cover. Identify primary power input connection block,chassis ground lug on the fan shroud frame, and primary input terminalboard.

Página 15

22Check the voltage links for proper volt-age on the Input Terminal board beforeapplying primary power.5. Figure 3-3 illustrates the input voltage ter

Página 16

23Table 3-2. Output Cable Sizes (Secondary)* Total cable length includes work and electrode cables. Cable size is based on directcurrent, insulated c

Página 17

24INSTALLATIONSECTION 3

Página 18

25SECTION 4OPERATION4.1. OPERATIONA. WIRE FEEDER COMPATIBILITYThe MultiPower 460 Pulse power source can be used with several types of wirefeeders. T

Página 19 - SECTION 3

26NOTEIf a Remote Hand Control is used for con-tinuous current control, place the PANEL/REMOTE switch in the PANEL POSITIONand set the Panel Current k

Página 20

27SECTION 4OPERATIOND. STICK WELDINGWhen the PROCESS switch is placed in the STICK position, the MultiPower 460Pulse establishes open circuit voltage

Página 21

28When the WELD PROCESS switch ismoved to the TIG or STICK position,electrode becomes electrically “HOT”.Do not allow the electrode to contactground p

Página 22

29SECTION 4OPERATIONF. MIG & FLUX CORE WELDING PRESET PROCEDUREWhen the PROCESS switch is placed in the MIG position, the MultiPower 460Pulse is

Página 23

3TABLE OF CONTENTSSECTION TITLE PAGESECTION 1 SAFETY ...

Página 24 - INSTALLATIONSECTION 3

30Table 4-2 Wire Types, Diameter and Shield GasesSECTION 4OPERATIONMaterial Type DiametersShielding Gas (AWS Designation)Carbon

Página 25 - OPERATION

31SECTION 4OPERATIONFigure 4-6 Synergic Pulse MIG Setup32514The TRIM Knob on the front panel (Voltage knob) allows the operator to fine tunethe puls

Página 26 - SECTION 4 OPERATION

32SECTION 4OPERATIONStep 6. Set the shielding gas flow rate to 35 cfh by activating the gas purgeswitch on the wire feeder or pulling the gun trigger

Página 27

33SECTION 4OPERATION3. SHIELDING GASESTable 4-2 lists the types of shielding gas mixtures that can be used with theMultiPower 460 Pulse. The wire b

Página 28

34SECTION 4OPERATIONJumper Plug Removed and Harness connected (as factory shipped)Non-Synergic Mode - The pulse parameters are determined by the posit

Página 29

35SECTION 5MAINTENANCEThese circuits are protected by two 10 amp circuit breakers mounted in the frontpanel. If these open, the contactor and wire fe

Página 30

36gCONDITION ACTIONUnit Inoperative A.B.C.D.E.No input power. Check main line (user's) switch fuses -- replace if needed.Poor or improper input

Página 31

37Schematic Diagram Section 1 - MultiPower 460 - 230/460/575V0558003034-C

Página 32

38Schematic Diagram Section 2 - MultiPower 460 - 230/460/575V0558003034-C

Página 33

39Schematic Diagram Section 3 - MultiPower 460 - 230/460/575V0558003034-C

Página 34

4TABLE OF CONTENTS

Página 35 - MAINTENANCE

40Wiring Diagram Section 1 - MultiPower 460 - 230/460/575V0558003064-D

Página 36

41Wiring Diagram Section 2 - MultiPower 460 - 230/460/575V0558003064-D

Página 37 - 0558003034-C

42Wiring Diagram Section 3 - MultiPower 460 - 230/460/575V0558003064-D

Página 38

43SECTION 6 REPLACEMENT PARTS6.1. REPLACEMENT PARTSReplacement Parts are illustrated on the following figures. When ordering replacement parts, order

Página 39

44SECTION 6 REPLACEMENT PARTS1234, 56798QTY. ITEM CIRCUITNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 2 678025 Ter

Página 40 - 0558003064-D

45SECTION 6 REPLACEMENT PARTSQTY. ITEM CIRCUITNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 2 678025 Terminal Asse

Página 41

46SECTION 6 REPLACEMENT PARTS621QTY. ITEM CIRCUITNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 0558004100 Kit, Puls

Página 42

4712345SECTION 6 REPLACEMENT PARTSQTY. ITEM CIRCUITNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 1 1312733 Label fo

Página 43 - SECTION 6 REPLACEMENT PARTS

48SECTION 6 REPLACEMENT PARTSQTY. ITEMNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 3 99511916 Diode Fwd 200V 250A2

Página 44

491234SECTION 6 REPLACEMENT PARTSQTY. ITEMNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 2 17280110 Res WW Fix'

Página 45

5WARNING: T hese Safety Precautions are foryour protection. They summarize precaution-ary information from the references listed inAdditional Safety I

Página 46

5012543SECTION 6 REPLACEMENT PARTSQTY. ITEMNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 1 952938 SCR 480V 18A Pane

Página 47

51REVISION HISTORY1. 07 / 2003 - "A" REVISION - Updated all front panel diagrams to show new layout, also updated front paneldiagram in repl

Página 48

IF YOU DO NOT KNOW WHOM TO CALLTelephone: (800) ESAB-123/ Fax: (843) 664-4452/ Web:http://www.esab.comHours: 7:30 AM to 5:00 PM ESTA. CUSTOMER SERVICE

Página 49

6FUMES AND GASES -- Fumes andgases, can cause discomfort or harm,particularly in confined spaces. Donot breathe fumes and gases. Shield-ing gases can

Página 50

7ADVERTENCIA: Estas Precauciones de Seguridadson para su protección. Ellas hacen resumen deinformación proveniente de las referencias listadasen la s

Página 51 - REVISION HISTORY

8HUMO Y GASES -- El humo y los gases,pueden causar malestar o daño,particularmente en espacios sinventilación. No inhale el humo o gases. Elgas de

Página 52 - 0558003754 03 / 2006

9coupes à l’arc, à moins de les recouvrir complètementd’une bâche non-inflammable. Ce type de matériauxcomprend notamment le bois, les vêtements, la s

Comentários a estes Manuais

Sem comentários