SECTION 3 INSTALLATION
ELECTRIC SHOCK CAN KILL! BEFORE MAKING ELECTRICAL INPUT
CONNECTIONS TO THE POWER SOURCE, "MACHINERY LOCKOUT
PROCEDURES" SHOULD BE EMPLOYED. IF THE CONNECTIONS ARE
TO BE MADE FROM A LINE DISCONNECT SWITCH, PLACE THE SWITCH
IN THE OFF POSITION AND PADLOCK IT TO PREVENT INADVERTENT
TRIPPING. IF THE CONNECTION IS MADE FROM A FUSE BOX, REMOVE
THE CORRESPONDING FUSES AND PADLOCK THE BOX COVER. IF IT
IS NOT POSSIBLE TO USE PADLOCKS, ATTACH A RED TAG TO THE
LINE DISCONNECT SWITCH OR FUSE BOX WARNING OTHERS THAT
THE CIRCUIT IS BEING WORKED ON.
Figure 3-3. Primary Power Leads L1,L2, L3 & Ground
Figure 3-2. Recommended Cable Strip Lengths
(3) PRIMARY
INPUT
CONDUCTORS
5"
24"
Green
(Earth Ground)
THE CHASSIS MUST BE CONNECTED TO AN APPROVED ELECTRICAL
GROUND. FAILURE TO DO SO MAY RESULT IN ELECTRICAL SHOCK,
SEVERE BURNS OR DEATH.
WARNING
WARNING
Primary Input
Connection Block
Chassis Ground Lug
Primary Input
Terminal Board