36
.045
.040
.035
1/16
.052
WIRE TYPE
WIRE DIAMETER
PULSE SELECTION
EN-625 ERNiCrMo-3
STAINLESS
AL-4000
AL-5000
EN-60 ERNiCu-7
METAL CORE
STEEL
STEEL
EN-67 ERCuNi
0
5
4
3
2
1
9
8
7
6
Voltage (CV)
Current (CC)
Trim (Pulse)
TEMP
POWER
BLINKING
WIRE SPEED
OUT OF RANGE
STEADY
NO PROGRAM
PRESET
MIG
LIFT
START
TIG
STICK
REMOTE
PANEL
STANDARD
MIG PULSE
Auto Fan
Fan will cycle automatically
Multipower 460PULSE
WFS-IPM
A
AMPS
V
VOLTS
SECTION 4 OPERATION
NOTE
When using the MP-460 Remote Pendant Con-
trol, place the PANEL/REMOTE switch in the
REMOTE position. This will defeat the MP-460
front panel voltage control. Voltage can then
be adjusted from the remote pendant
5
Figure 4-6
Contactor Switch for "Off the
Arc" wire feeders
Figure 4-7 Synergic Pulse MIG Setup
3
2
5
1
4
G. Pulse Mig Setup
Connect wire feeder to MultiPower 460 Pulse and set PANEL/REMOTE switch to PANEL position.
Set the STANDARD/MIG PULSE switch to the MIG PULSE position.
Place the WELD PROCESS switch in the MIG (center) position.
Set the PULSE SELECTION switches to the WIRE TYPE and DIAMETER installed on the wire feeder.
Press and release the PRESET button then turn the TRIM knob to the approximate welding wire feed speed
needed for the wire type and size to be used. If the MIG CONTACTOR is in the “ON” position the PRESET button
must be held down to preset the wire feed speed.
Flip the CONTACTOR switch on the MP-460 auxiliary panel to the “ON” position. See Fig. 4-6.
Turn the wire speed knob on the wire feeder to the desired wire feed speed.
Connect the work cable from the MP-460 and the voltage pick-up lead from the wire feeder to the part to be
welded.
Activate the gas purge switch if the wire feeder has this feature. If not, release the pressure roll so wire does not
feed. Pull the gun trigger and set the shielding gas flow rate by turning the adjustment knob on the shield gas
flowmeter to the recommended gas flow (typically 35 cfh).
Engage the drive stand pressure roll and begin welding by pulling the gun trigger. Trim the arc length using the
wire speed control knob on the wire feeder. Adjust the heat content of the arc by increasing or decreasing the
Trim knob on the MP-460 Pulse front panel.