32
C. Tig Welding (Lift Start Tig)
When the PROCESS switch is placed in the LIFT START TIG position, the MultiPower 460 Pulse is automatically set for CC
(constant current) welding using the ESAB Lift Start TIG starting method. The voltage and current at the output terminals
are maintained at low values until the electrode is shorted to the workpiece then “lifted” to create the welding arc.
Be sure to set the polarity to DCEN (Electrode Negative) by connecting the Tig torch to the negative terminal lug
on the front of the power source.
Place the WELD PROCESS switch in the LIFT START TIG position.
Place the PANEL/REMOTE switch in the PANEL position.
Place STANDARD/MIG PULSE switch in the STANDARD position.
While depressing the PRESET button, turn the VOLTAGE/CURRENT knob to the desired weld current as displayed
on the top digital display window.
Set the shielding gas flow rate to a desired flow by adjusting the adjustment knob on the flowmeter. (20 cfh is
typically recommended)
Touch the tungsten electrode to the workpiece momentarily then lift the electrode 1/16" off the workpiece to
establish the welding arc. Trim the weld current as desired by turning the VOLTAGE/CURRENT knob.
1.
2.
3.
4.
5.
6.
7.
SECTION 4 OPERATION
NOTE
When using a remote current device with the MP-460 Pulse, the STANDARD/MIG PULSE switch must be in
the STANDARD position for proportional current control. Set the current knob on the MP-460 Pulse front
panel to the maximum desired weld current using the procedure above. The remote device will then
control the current proportionally between the minimum current setting of 5 amps and maximum set on
the MP-460 front panel. The maximum Tig welding current is 525 amps.
If the MP-460 PANEL/REMOTE switch is left in the REMOTE position while using a remote control option
device, the current range will be full scale or 10 to 400 amps on the remote device. Adjustment of the
maximum current on the MP-460 Pulse front panel is defeated.
5
4
2
3
.045
.040
.035
1/16
.052
WIRE TYPE
WIRE DIAMETER
PULSE SELECTION
EN-625 ERNiCrMo-3
STAINLESS
AL-4000
AL-5000
EN-60 ERNiCu-7
METAL CORE
STEEL
STEEL
EN-67 ERCuNi
0
5
4
3
2
1
9
8
7
6
Voltage (CV)
Current (CC)
Trim (Pulse)
TEMP
POWER
BLINKING
WIRE SPEED
OUT OF RANGE
STEADY
NO PROGRAM
PRESET
MIG
LIFT
START
TIG
STICK
REMOTE
PANEL
STANDARD
MIG PULSE
Auto Fan
Fan will cycle automatically
Multipower 460PULSE
WFS-IPM
A
AMPS
V
VOLTS
When the WELD PROCESS switch is moved to the TIG or STICK position,
electrode becomes electrically “HOT”. Do not allow the electrode to
contact ground potential until you are ready to make a weld.
CAUTION
Figure 4-1 Standard Tig Setup Procedure