SECTION 3 INSTALLATION
CHECK THE VOLTAGE LINKS FOR PROPER VOLTAGE ON THE INPUT
TERMINAL BOARD BEFORE APPLYING PRIMARY POWER.
Figure 3-4. Input Terminal Board Configuration for 230/460 Model
(208)230 Vac Input
Note: For 208 vac use 230 vac linking
460 Vac Input
WARNING
Figure 3-4 illustrates the input voltage terminal boards and the input voltage link connections. The particular
voltages from which this power source may be operated are stated on the rating plate. The voltage links were
factory set for highest voltage stated on the rating plate (460 VAC). If the power source is to be operated on
another stated input voltage, the links must be reset for that particular input voltage. Always verify the input
voltage and check the link arrangement regardless of factory setting. The voltage links are set up by reconfigur-
ing the copper link bars to the silk-screened voltage designations for the desired voltage.